Quiz Summary
0 of 20 Questions completed
Questions:
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
0 of 20 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- Not categorized 0%
-
CLICK HERE to go back to the ECC Testing Center
Click View Questions button below to see the questions and custom feedback.
Please text 423-895-3247 if you need help or these tests are glitching.
Thanks!!
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- Current
- Review
- Answered
- Correct
- Incorrect
-
Question 1 of 20
1. Question
For a single-phase 240V residential service, what is the minimum size of the grounding electrode conductor (GEC) for a service with 3/0 AWG copper ungrounded conductors?
CorrectIncorrect -
Question 2 of 20
2. Question
What is the secondary voltage of a transformer that has a 4:1 turn ratio and a primary voltage of 480?
CorrectIncorrect -
Question 3 of 20
3. Question
What is the demand factor for 18 shore power receptacles?
CorrectIncorrect -
Question 4 of 20
4. Question
What is the Voltage drop of a 200 amp circuit using 4/0 copper conductors that is 225 ft long on a 120/240 system?
CorrectIncorrect -
Question 5 of 20
5. Question
What is the allowable ampacity of a #10 THWN-2 copper conductor in an area with an ambient temperature of 114°F in a conduit with 4 current carrying conductors?
CorrectIncorrect -
Question 6 of 20
6. Question
How many #8 conductors can you fit into a 4 x 1 1/4 round/octagonal box?
CorrectIncorrect -
Question 7 of 20
7. Question
What is the total cubic fill you would calculate for 5 #12 conductors and 6 #10 conductors?
CorrectIncorrect -
Question 8 of 20
8. Question
What is the voltage across an open switch when the voltage supplying the switch is 120v?
CorrectIncorrect -
Question 9 of 20
9. Question
What size copper conductor would you select for 4 motors with FLC’s of 22 amps, 20 amps, 14 amps, and 10 amps terminating to 75 C terminals?
CorrectIncorrect -
Question 10 of 20
10. Question
What size copper conductors would you select for a single phase motor with a nameplate rating of 26 amps that will run a draw bridge for only 5 mins at a time and terminating to 60 C lugs?
CorrectIncorrect -
Question 11 of 20
11. Question
Bundling adjustment factors do not do need to be considered when nipples are _____ inches or less.
CorrectIncorrect -
Question 12 of 20
12. Question
What is the total resistance of this parallel circuit?
CorrectIncorrect -
Question 13 of 20
13. Question
Cable trays containing conductors rated over 600 V shall have permanent, legible warnings stating _____.
CorrectIncorrect -
Question 14 of 20
14. Question
Outdoor overhead conductors over _____ volts shall be permitted only for systems rated over ______ volts.
CorrectIncorrect -
Question 15 of 20
15. Question
6 inch PVC must be supported at a minimum of every __________ Ft.
CorrectIncorrect -
Question 16 of 20
16. Question
All receptacles within ____________ ft of a pool or spa must be GFCI protected.
CorrectIncorrect -
Question 17 of 20
17. Question
Cord and plug connected office luminaries must not exceed ___________ ft in length.
CorrectIncorrect -
Question 18 of 20
18. Question
For sign ballasts, secondary-circuit voltages shall not exceed _______________ volts.
CorrectIncorrect -
Question 19 of 20
19. Question
What is the total calculated load for eight 5,000 watt dryers using the standard method?
CorrectIncorrect -
Question 20 of 20
20. Question
What is the total calculated demand for one 10.5 Kw range?