Quiz Summary
0 of 40 Questions completed
Questions:
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
0 of 40 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- Not categorized 0%
-
CLICK HERE to go back to the ECC Testing Center
Click View Questions button below to see the questions and custom feedback.
Please text 423-895-3247 if you need help or these tests are glitching.
Thanks!!
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- 27
- 28
- 29
- 30
- 31
- 32
- 33
- 34
- 35
- 36
- 37
- 38
- 39
- 40
- Current
- Review
- Answered
- Correct
- Incorrect
-
Question 1 of 40
1. Question
How many receptacles are required in patient bed (category 1) locations ?
CorrectIncorrect -
Question 2 of 40
2. Question
Live parts on generators operating at more than __________ VOLTS AC shall not be exposed in a way where accidental contact can be made.
CorrectIncorrect -
Question 3 of 40
3. Question
Mobile home power cords must be at least 21 ft. in length but must not be more than ____________ ft.
CorrectIncorrect -
Question 4 of 40
4. Question
Network powered broad brand shall maintain a separating of at least _________ ft. from lighting conductors.
CorrectIncorrect -
Question 5 of 40
5. Question
On portable staging equipment for luminaries the cord length shall not exceed __________ ft.
CorrectIncorrect -
Question 6 of 40
6. Question
Overhead communication wires near service drops not exceeding 750 volts must have a clearance of ________ inches. of the service drop?
CorrectIncorrect -
Question 7 of 40
7. Question
Power cords for mobile homes must not exceed ________ amps?
CorrectIncorrect -
Question 8 of 40
8. Question
Traveling cables for lighting circuits in elevators must have an equivalent ampacity of ________ awg copper.
CorrectIncorrect -
Question 9 of 40
9. Question
What does the T stand for on THHN Wire?
CorrectIncorrect -
Question 10 of 40
10. Question
What is the ampacity of #14 awg copper fixture wire?
CorrectIncorrect -
Question 11 of 40
11. Question
What does the N in THHN Stand for?
CorrectIncorrect -
Question 12 of 40
12. Question
What is the demand factor for 18 shore power receptacles?
CorrectIncorrect -
Question 13 of 40
13. Question
What is the Duty Cycle demand factor for a resistance welder with a 40% duty cycle?
CorrectIncorrect -
Question 14 of 40
14. Question
What is the locked rotor KVA per horsepower of a motor with a N code letter?
CorrectIncorrect -
Question 15 of 40
15. Question
What is the Total demand for 12 RV sites that are equipped with both 20 and 30 amp set ups?
CorrectIncorrect -
Question 16 of 40
16. Question
What is the Total demand for 25 RV sites that are equipped with 20 and 30 amp set ups?
CorrectIncorrect -
Question 17 of 40
17. Question
What size aluminum wire would you select for a piece of equipment with a load of 105 amps terminating to 75°C Terminals?
CorrectIncorrect -
Question 18 of 40
18. Question
What size aluminum wire would you select for a piece of equipment with a load of 145 amps terminating to 75°C Terminals?
CorrectIncorrect -
Question 19 of 40
19. Question
What size aluminum wire would you select for a piece of equipment with a load of 145 amps terminating to 75°C Terminals?
CorrectIncorrect -
Question 20 of 40
20. Question
How high must type NPLFA fire alarm cable be protected when penetrating through a floor?
CorrectIncorrect -
Question 21 of 40
21. Question
For sign ballasts, secondary-circuit voltages shall not exceed _______________ volts.
CorrectIncorrect -
Question 22 of 40
22. Question
For emergency stand by generators that require more than ________ seconds to develop power are permitted to have an auxiliary power supply.
CorrectIncorrect -
Question 23 of 40
23. Question
What is the minimum size round/octagonal box would be required to fit five #12 Conductors?
CorrectIncorrect -
Question 24 of 40
24. Question
What is the maximum cross sectional area you can fill of a pipe if you only have 1 conductor?
CorrectIncorrect -
Question 25 of 40
25. Question
What size copper conductors would you select for 5 motors with FLC’s of 24 amps, 13 amps, 13 amps, 10 amps, 9 amps terminating to 60° C terminals?
CorrectIncorrect -
Question 26 of 40
26. Question
What is the allowable ampacity of a 3/0 USE-2 aluminum conductor with an ambient temperature 16° C?
CorrectIncorrect -
Question 27 of 40
27. Question
What is the minimum overhead clearance for service conductors that pass over residential driveways, property, and commercial areas without truck traffic, not over 300V?
CorrectIncorrect -
Question 28 of 40
28. Question
Temporary electric power and lighting installations shall be permitted for a period not to exceed ______ days for holiday decorative lighting and similar purposes.
CorrectIncorrect -
Question 29 of 40
29. Question
For kitchen counter tops, what is the minimum width needed to require a receptacle?
CorrectIncorrect -
Question 30 of 40
30. Question
What is the total resistance of this parallel circuit?
CorrectIncorrect -
Question 31 of 40
31. Question
Strut-type channel raceway when surface mount shall be strapped at intervals not exceeding ______ ft.
CorrectIncorrect -
Question 32 of 40
32. Question
When installing fixed luminaries in a class I garage, the light shall be installed at least _____ ft. above the finished floor.
CorrectIncorrect -
Question 33 of 40
33. Question
What is 5,000 Va when converted to kVa?What is the multiplier for a continuous load?
CorrectIncorrect -
Question 34 of 40
34. Question
Electric pool water heaters shall have the heating elements subdivided into loads that no do not exceed _____ amps and protected from over ______ amps.
CorrectIncorrect -
Question 35 of 40
35. Question
Round down when your load calculation results in .49 or less?
CorrectIncorrect -
Question 36 of 40
36. Question
When a branch circuit is servicing sensitive electronic equipment, what is the maximum voltage drop % allowed?
CorrectIncorrect -
Question 37 of 40
37. Question
How many 8 AWG THHN conductors can be accommodated in a 1-1/2″ Electrical Metallic Tubing (EMT)?
CorrectIncorrect -
Question 38 of 40
38. Question
How many 10 AWG THWN-2 conductors can be accommodated in a 1″ Intermediate Metal Conduit (IMC)?
CorrectIncorrect -
Question 39 of 40
39. Question
What is the total demand for 9x 4,800 watt dryers using the standard method?
CorrectIncorrect -
Question 40 of 40
40. Question
A single-phase transformer with a primary voltage of 240V and a secondary voltage of 120V has a rated primary current of 20A. Calculate the rated secondary current of the transformer.
CorrectIncorrect