Quiz Summary
0 of 20 Questions completed
Questions:
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
0 of 20 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- Not categorized 0%
-
CLICK HERE to continue the program.
Click View Questions button below to see your answers and the custom feedback!
If these tests are glitching on you please text me the problems you are having 423-895-3247
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- Current
- Review
- Answered
- Correct
- Incorrect
-
Question 1 of 20
1. Question
A ground rod or pipe shall be allowed to be installed at up to a ______ degree angle if rock is encountered.
CorrectIncorrect -
Question 2 of 20
2. Question
At a minimum, how many 120v 20 amp circuits must a dwelling unit have?
CorrectIncorrect -
Question 3 of 20
3. Question
In classified locations, when using NPT fittings, how many threads should be engaged?
CorrectIncorrect -
Question 4 of 20
4. Question
.W4 Of the following wire types, what wire can you not put in a plenum?
CorrectIncorrect -
Question 5 of 20
5. Question
There shall be an air space of at least _____ between live parts, including metal parts that are live and enclosed overcurrent devices, and the door on equipment is rated 251v – 1,000v nominal.
CorrectIncorrect -
Question 6 of 20
6. Question
What is the demand factor for one 9.5 Kw range?
CorrectIncorrect -
Question 7 of 20
7. Question
What is the maximum weight a ceiling fan box box can hold without special attachment means?
CorrectIncorrect -
Question 8 of 20
8. Question
What is the minimum width that a kitchen counter top is required to be to need a receptacle?
CorrectIncorrect -
Question 9 of 20
9. Question
What is the total calculated demand for five 5 Kw ranges?
CorrectIncorrect -
Question 10 of 20
10. Question
What is the total calculated demand for one 10.5 Kw range?
CorrectIncorrect -
Question 11 of 20
11. Question
What is the total calculated demand for two, 10 Kw ranges?
CorrectIncorrect -
Question 12 of 20
12. Question
What type of communication cable is allowed to be run in a plenum?
CorrectIncorrect -
Question 13 of 20
13. Question
When 1 ground rod or pipe is _____ ohms or less, an additional electrode is not required.
CorrectIncorrect -
Question 14 of 20
14. Question
When a branch circuit supplies neon signs, it shall not exceed ______ amperes.
CorrectIncorrect -
Question 15 of 20
15. Question
When emerging from grade, underground wire should be protected from physical damage for a minimum of _____ ft.
CorrectIncorrect -
Question 16 of 20
16. Question
In dwelling units, no less than one 15 or 20 amp receptacle shall be installed within _____ ft. of refrigeration or HVAC Equipment.
CorrectIncorrect -
Question 17 of 20
17. Question
Using the optional method, what size over-current protection would you select for a load calculated at a total of 68,000 Va on a 120/240 system?
CorrectIncorrect -
Question 18 of 20
18. Question
The disconnect for low-voltage suspended ceiling power distribution systems must be _____, and within sight of the class 2 power source.
CorrectIncorrect -
Question 19 of 20
19. Question
A ladder that is 12 ft. tall is required to be set with the base how many feet away from the wall?
CorrectIncorrect -
Question 20 of 20
20. Question
MC cables shall be supported at intervals not exceeding _____ ft.
CorrectIncorrect