Quiz Summary
0 of 20 Questions completed
Questions:
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
0 of 20 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- Not categorized 0%
-
CLICK HERE to continue the program.
Click View Questions button below to see your answers and the custom feedback!
If these tests are glitching on you please text me the problems you are having 423-895-3247
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- Current
- Review
- Answered
- Correct
- Incorrect
-
Question 1 of 20
1. Question
Cable trays containing conductors rated over 600 V shall have permanent, legible warnings stating _____.
CorrectIncorrect -
Question 2 of 20
2. Question
Class I division 2 pendant luminaries, with rigid stems larger than _____ inches, shall provide permanent and effective bracing against lateral displacement.
CorrectIncorrect -
Question 3 of 20
3. Question
For heaters that are installed in a Class I division 2 area, the heater shall not be in excess of _____% of the auto-ignition temperature in degrees Celsius.
CorrectIncorrect -
Question 4 of 20
4. Question
For kitchen counter tops, what is the minimum width needed to require a receptacle?
CorrectIncorrect -
Question 5 of 20
5. Question
For meeting rooms at least 12 ft. wide and 215 sq. ft., there are required to be a minimum of _____ floor receptacle outlet(s).
CorrectIncorrect -
Question 6 of 20
6. Question
For mobile homes, when bonding the non-current carrying metal parts, you must use a minimum of _____ Awg conductor(s).
CorrectIncorrect -
Question 7 of 20
7. Question
In a Class I Division 2 boundary the sealing fitting shall be permitted to be installed on either side of the boundary, within _____ ft. of the boundary.
CorrectIncorrect -
Question 8 of 20
8. Question
In dwelling units, no less than one 15 or 20 amp receptacle shall be installed within _____ ft. of refrigeration or HVAC Equipment.
CorrectIncorrect -
Question 9 of 20
9. Question
Metal underground gas pipe is permitted to be used as a grounding electrode conductor?
CorrectIncorrect -
Question 10 of 20
10. Question
Outlet boxes shall be installed when on concrete, gypsum, plaster, or other non-combustible material set back no farther than _____ from the finish surface.
CorrectIncorrect -
Question 11 of 20
11. Question
Using the optional method, what size over-current protection would you select for a load calculated at a total of 68,000 Va on a 120/240 system?
CorrectIncorrect -
Question 12 of 20
12. Question
What color should you use to mark the high leg of a 4-wire, delta connected system?
CorrectIncorrect -
Question 13 of 20
13. Question
What is the Va calculation per 1 ft. for multi-outlet assemblies that are going to used simultaneously?
CorrectIncorrect -
Question 14 of 20
14. Question
What table do you use for lighting load demand factors?
CorrectIncorrect -
Question 15 of 20
15. Question
How many amps would a 100W light bulb draw on a 120v circuit?
CorrectIncorrect -
Question 16 of 20
16. Question
When branch circuits supply neon tubing luminaries they shall be on a circuit that is in not in excess of _____ amps.
CorrectIncorrect -
Question 17 of 20
17. Question
When emerging from grade, underground wire should be protected from physical damage for a minimum of _____ ft.
CorrectIncorrect -
Question 18 of 20
18. Question
When 1 ground rod or pipe is _____ ohms or less, an additional electrode is not required.
CorrectIncorrect -
Question 19 of 20
19. Question
What type of communication cable is allowed to be run in a plenum?
CorrectIncorrect -
Question 20 of 20
20. Question
When a branch circuit supplies neon signs, it shall not exceed ______ amperes.